INDUCTION HEAT TREATMENT

  The roll bodies hardening is executed in the automated induction hardening facility with induction heating. This provides recurrence of the hardening results. Hardness variation does not exceed 2-3 HSD. The work rolls have the depth of the effective case up to 45 mm, the backup rolls - up to 60 mm along the radius.
  To harden the necks for the bodies hardness of 45 HSD the technology of hardening with high-frequency heating is introduced in the Company.
Induction heat treatment